Spirotech Magnabooster

The SpiroTrap MagnaBooster² offers a completely universal unit suitable for vertical, horizontal or even diagonal installations. The unit delivers a simple and efficient way to remove all types of dirt, debris and sludge from central heating systems.

Fitted by British Gas and recommended for british gas dirt removal:

Features and Benefits:

  • Easy to install and suitable for vertical, horizontal and even diagonal installations.
  • Unique dual action removes both magnetic and non-magnetic dirt.
  • Keeps heating systems running at their maximum efficiency.
  • Proven energy efficiency by BSRIA.
  • British Gas Dirt Removal
  • Cleaned in seconds with no need to remove the magnet or the unit from the system.
  • Slim design constructed from robust brass (no service kits required).
  • Available with 22mm or 28mm fittings (no isolation valves required).
  • INDUSTRY LEADING 20 year guarantee*

How it works
 
A new TWIST on the removal of dirt from heating systems.

The SpiroTrap MagnaBooster² offers a completely universal unit suitable for vertical, horizontal or even diagonal installations. The unit delivers a simple and efficient way to remove all types of dirt, debris and sludge from central heating systems.

So how does the MagnaBooster² work?

 

How to install

Installation/Operating instructions for the Spiro Trap MagnaBooster²

Installing the SpiroTrap MagnaBooster²

The SpiroTrap MagnaBooster² should be installed preferably before the components to be protected: i.e. Boiler, Pump etc.

  • Drain down the central heating system.
  • Fit the SpiroTrap MagnaBooster² preferably on the boiler return pipe work as near to the boiler as possible.
  • The arrow on the unit indicates the direction that the water should flow through the unit.
  • Measure & remove the section of pipe (68mm maximum) where the SpiroTrap MagnaBooster² will be installed.
  • For installation on to rigid pipe work the Magnabooster² has been designed with this in mind and one of the internal pipe connections is longer than is normally required and acts as a slip socket.
  • You can slide the pipe into the unit and then slide the unit across in the opposite direction and connect onto the pipe opposite.
  • It is important that the pipe is fully inserted into this connection.
  • Ensure the body of the unit is positioned vertically (see the drawings).
  • Hand tighten the ring nut, and then tighten normally to achieve the final seal.
  • Install the supplied drain valve to the bottom of the SpiroTrap MagnaBooster²: shut off the valve using the safety cap as the valve key, then screw the safety cap back on to the drain valve.
  • The drain valve can be used to drain the system.
  • Make sure that the drain valve is always accessible.
  • Drain the SpiroTrap MagnaBooster² regularly; once a year is recommended.
  • Important never use the drain valve as a filling valve
Where can i buy the new magnabooster or magnabooster 2 ?
Ring me for more details 07725 692699