Sabre HE
Here at cheap central heating we believe in giving the customer the choice of what boiler they would like and realise that although we would all like to have the best sometimes our budget means that we cannot have what we want.
We can install any boiler that you like just give us a call and ask us for our best offers. 07725 692699
INTRODUCTION
Sabre 25HE 10.2 l/min
The Sabre HE range of appliances is comprised of 2 models of high-efficiency combination boiler with inputs to heating & DHW of 25, 29 & 35kW respectively. Each appliance - by design - incorporates electronic ignition, circulating pump, expansion vessel, safety valve, pressure gauge and automatic by-pass. The Sabre HE range is produced as room sealed, category II2H3P appliances, suitable for internal wall mounting applications only. They are provided with a fan powered flue outlet with an annular coaxial combustion air intake that can be rotated - horizontally - through 360 degrees for various horizontal or vertical applications. The Sabre HE range is approved for use with C12 & C32 type flue applications. These appliances are designed for use with a sealed system only; consequently they are not intended for use on open vented systems
SECTION 1 DESIGN PRINCIPLES AND OPERATING SEQUENCE
1.1 PRINCIPLE COMPONENTS A fully integrated electronic control board featuring electronic temperature control, anti-cycle control, pump over-run, LED fault indicator, full gas modulation. Low-water-content, copper heat exchanger. Electronic ignition with flame supervision. Integral high-head pump. Fan. Air pressure switch. Expansion vessel. Water pressure switch. Two-stage gas valve. Pressure gauge. Safety valve. Condense switch. 1.2 MODE OF OPERATION (at rest) When the appliance is at rest and there are no requests for heating or DHW, the following functions are active: Frost-protection system: the frost-protection system protects the appliance against the risk of frost damage. Should the temperature of the appliance fall to 5 °C, the boiler will function in the heating mode at minimum power until it reaches 35 °C. Anti-block function: the anti-block function enables the pump and divertor valve actuator, to be energised for short periods, when the appliance has been inactive for more than 19-hours. 1.3 MODE OF OPERATION (Heating) When there is a request for heat via the time clock and/or any external control, the pump and fan are started, the fan will then prove the air pressure switch. At this point an ignition sequence is enabled. Ignition is sensed by the electronic circuitry to ensure flame stability at the burner. Once successful ignition has been achieved, the electronic circuitry increases the gas rate to 75% for a period of 15 minutes. Thereafter, the boiler’s output will either be increase to maximum or modulate to suit the set requirement. When the appliance reaches the desired temperature the burner will shut down and the boiler will perform a three-minute anti-cycle (timer delay). When the request for heat has been satisfied the appliance pump and fan may continue to operate to dissipate any residual heat within the appliance. 1.4 MODE OF OPERATION (DHW) When there is a request for DHW via a hot water outlet or tap, the pump and fan are started, the fan will then prove the air pressure switch. At this point an ignition sequence is enabled. Ignition is sensed by the electronic circuitry to ensure flame stability at the burner. Once successful ignition has been achieved, the electronic circuitry increases the gas rate to maximum or will modulate output to stabilise the temperature. In the event of the appliance exceeding the desired temperature the burner will shut down until the temperature drops. When the request for DHW has been satisfied the appliance pump and fan may continue to operate to dissipate any residual heat within the appliance. 1.5 SAFETY DEVICES When the appliance is in use, safe operation is ensured by: A water pressure switch that monitors system water pressure and will deactivate the pump, fan and burner should the system water pressure drop below the rated tolerance. A high limit thermostat that over-rides the temperature control circuit to prevent or interrupt the operation of the burner. An air pressure switch that requires the fan to prove operation before the gas valve is energised. A pressure switch that interrupts the operation of the appliance if the condense pipe becomes blocked. A safety valve which releases excess pressure CH from the primary circuit.
if you would like a full written quotation click here or ring me now on 07725 692699
Sabre 25HE boiler only
Boiler buddy page click here Magnaclean page click here Powerflushing page click here Boiler advice page click here